The PF1300 is a Flare Ignition System designed for open flare stack and flare pit applications. By monitoring flame status, providing dependable re-ignition, and relaying flame status, the PF1300 drastically reduces the frequency that an operator must visit the flare site.
It is also available with an optional integrated 12V battery and charge controller for use with solar panel installations. This permits reliable operation on sites where power is not readily available. Solar can also be used on sites where power is already available, though uninterrupted operation is required in the event of a power outage.
Integrated status contacts allow for local alarm and or remote monitoring capability.
Power Supply Requirements | VALUE |
---|
Base Model (SC000) | 12/24 VDC |
Battery Model (SCB00) | 12V Solar Panel (40W Max) |
Power Consumption | 12VDC | 24VDC |
---|
Average Current (When not Sparking) | 30 mA | 30 mA |
Peak Current (When Sparking) | 4 A | 4 A |
Average Current (When Off) | 3 mA | 3 mA |
Ignition Voltage | Up to 20 kV | Up to 40 kV |
Temperature Ratings | Min | Max |
---|
Operating Range (SC000) | -40°C (-40°F) | +80°C (+176°F) |
Operating Range (SCB00) | -40°C (-40°F) | +50°C (+122°F) |
Storage Range (SC000) | -40°C (-40°F) | +85°C (+185°F) |
Storage Range (SCB00) | -40°C (-40°F) | +60°C (+140°F) |
Terminal Blocks | VALUE |
---|
Maximum Wire Gauge | 12 AWG |
Status Contact | VALUE |
---|
Type | Dry |
Max Voltage | 200 V (Peak AC or DC) |
Max Continuous Current | 150 mA |
Impedance (When Closed) | 5Ω |
Physical Dimensions | VALUE |
---|
Width | 30.9 cm (12.15 in) |
Height | 23.4 cm (9.23 in) |
Depth | 13.4 cm (5.28 in) |
Weight | VALUE |
---|
Base Model (SC000) | 3.2 kg (7.0 lbs) |
Battery Model (SCB00) | 6.0 kg (13.5 lbs) |