Introducing:
Compliant with modern safety regulations (CAN and US) for use with enclosed fire tubes and burners. By monitoring burner flame status, ensuring effective temperature management, and guaranteeing reliable re-ignition, the PF2100 helps optimize oilfield operations.
12 VDC*: 1.1 W typical (92mA typical**, 5A max)
24 VDC*: 1.4 W typical (60mA typical**, 5A max)
*System voltage must match valve rating
**Not including valves, display off
-40°C to 55°C (-40°F to 130°F)
1 Ignition Coil Output
1 Flame Detection Input
3 Thermocouple Inputs
6 Dry Contact Inputs for safety interlock device connections
1 Dry Status Contact Output
3 Valve Control Outputs
1 Programmable 4-20mA Output
2 4-20mA Inputs
1 NO/NC Dry Contact Output
Dry, Max 40VDC, Max 250mA continuous
309 x 234 x 134 mm (12.15" x 9.23" x 5.28")
2.3 kg (5 lbs)
Class 1 Division 2, Group A, B, C, and D; T4A, Type 4X
Ex nA IIC T4 IP66
Class 1, Zone 2, AEx nA IIC T4 IP66
ANSI Z21.20
ANSI-ISA-12.12.01-2007
CSA 22.2 No. 199
CSA C22.2 No. 213-M1987
CSA C22.2 No. 0-M91
CSA C22.2 No. 0.4-04
CSA C22.2 No. 94-91
CSA C22.2 No. 142-M1987
CSA E60079-0:2007
CSA E60079-15:2005
UL 372