PF2100f

Monitor flare status and provide dependable re-ignition

The PF2100F

Flare Ignition System
Intuitive and clear
programming menus
12V or 24V operation supported
low power
On Demand or Fixed Interval spark option using:
Flame Detection
Thermocouple
Ionization

  • Optional Modbus RS485 communication
  • Optional High Temperature Shutdown
  • Pilot solenoid control
  • Programmable set-points for Alarm and Temperature
  • Designed and tested to operate over a wide range of ambient temperatures (-40°C to +65°C)
  • Class 1 Division 2, NEMA 4X enclosure
  • See overview description below for details regarding additional zoning capability


Get A Quote Share Product
Applications

  • Flare Pits
  • Flare Stacks

Class 1, Division 2, Grp ABCD; T4A
CSA Type 4X
CSA C22.2 No. 0-M91
CSA C22.2 No. 0.4-04
CSA C22.2 No. 94-91
CSA C22.2 No. 142-M1987
CSA C22.2 No. 213-M1987
CSA E60730-1:02
CSA E60079-0:2007
CSA E60079-1

Power Supply RequirementsVALUE
Base Model12/24 VDC
Power Consumption12VDC24VDC
Controller Only (Display On)2.6 W2.9 W
Controller Only (Display Off)1.1 W1.2 W
Max Total Current Draw5 A5 A
Max Valve Current Draw2 A2 A
Ignition Voltage (Internal Coil)Up to 20kVUp to 40kV
Temperature RatingsMinMax
Operating Range-40°C (-40°F)+55°C (+130°F)
Storage Range-40°C (-40°F)+80°C (+176°F)
Terminal BlocksVALUE
Maximum Wire Gauge12 AWG
Status ContactVALUE
TypeDry
Max Voltage40 VDC
Max Continuous Current250 mA
Impedance (When Closed)15?
Physical DimensionsVALUE
Width30.9 cm (12.15 in)
Height23.4 cm (9.23 in)
Depth13.4 cm (5.28 in)
WeightVALUE
Base Model4.0 lbs (1.8kg)
Base Model Plus 1 Expansion Card4.5 lbs (2.0 kg)
Base Model Plus 2 Expansion Cards6.0 lbs (2.6 kg)

Why Choose the PF2100F?

Reliable Flame Detection
Available Remote Control
Low Power

Need help?

We've got you

1